Small Mechanical Flowmeters with Nylon End Caps

NEW! Reinforced Nylon End Caps reduce weight and cost
of proven mechanical flowmeter design.
Stainless steel stabilizer ring holds threads stable, preventing distortion.
Nylon material provides dielectric insulator to help prevent galvanic action due to dissimilar metals.
General Description
• Smartflow® mechanical flowmeters are durable, vaneoperated devices that provide visual indication
of flow rate in many different styles and sizes. Rugged wetted parts are compatible with many process
liquids.
• Optional temperature and pressure gauges add functionality and flexibility to Smartflow® flowmeters.
• Brass quick-connect fittings are available to create an excellent, portable tool for determining flow
and locating clogged lines.
• Stainless Steel Stabilizer Ring!
Features and Benefits
• Compact size works well in restricted-space locations.
• Rugged construction gives years of dependable service.
• Variety of inlet sizes provides exactly the right connection.
• 210°F (99°C) Temperature Rating allows installation into a wide range of applications.
• Optional Temperature and Pressure Gauges display pressure and temperature information in addition to flow in one unit.
• Common Flowmeter Configurations Stocked to provide same-day delivery in most cases.
• No Mounting Restrictions ease installation in any position without extra brackets or hardware.
Wetted Parts and Materials
End Caps ..............................................Glass-Filled Nylon
Flow Body ............................................Polysulfone
Vane ......................................................Glass-Filled Nylon
Spring....................................................Stainless Steel
O-Rings ................................................EPDM
Cap Screws ..........................................Zinc-Plated Steel
Optional Quick-Connect Fittings........Brass
Specifications
Flow Accuracy ........................................±10% full scale
Operating Temperature..........................210°F max. (99°C max.)
Operating Pressure ................................75 psi max. (5.2 bar max.)
Dial Thermometer ..................................0° to 250°F (-20° to 120°C) ±2% accuracy (full scale)
Pressure Gauge ......................................0 to 100 psi (0 to 700 Kpa) ±3% accuracy (full scale)

Current pricing on small mechanical flowmeters
| Northern Supply 1901 Oakcrest Ave St. Paul, MN 55113 800-365-6565 |
Nickerson P.O. Box 213 Accord, MA 02018 800-821-9534 |
OHS Toronto 6210 N.W. Drive Mississauga, ON L4V 1J6 888-809-7050 |
OHS Montreal 2912 J.A. Bombardier Laval, OQ H7P 6E3 888-475-9224 |